SDR 06FDEA2718

Service difficulty report · Controller · Airbus A310

Difficulty date
July 28, 2006
Submitted
July 31, 2006
Operation
Air carrier
Aircraft
N417FE
Make and model
Airbus A310
Aircraft serial
333
Aircraft time
40,776 hours, 20,646 cycles
Part
Controller
Condition
Malfunctioned
Location
Cabin Pressure
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 417, 21-30, 0009646, 28JUL06 SIN, AFTER TAKEOFF RECEIVED ECAM ALERT (EXCESS CAB ALT) WENT TO RED TABS AND COULD NOT CONTROL CABIN PRESSURE. ON ECAM NR1 OUTFLOW VALUE OPEN , NR2 OUTFLOW CLOSED FACT, 28JUL06 09:49 SIN R R/I NR1 CABIN PRESSURE CONTROLLER AND PERFORM TEST ON CABIN PRESSURE CONTROLLER AND OK IAW MM21-31-00-5-01. PERFORM VISUAL CHECK ON NR1 OUTFLOW VALVES (FWD AND AFT) IN OPEN AND CLOSED POSITION AND FOUND OK. R/I 28JUL06 09:50 SIN R R/I FROM FACT, OFF MFG 82010B040901, POS LT, SRL 235 ON MFG 82010B040901 SRL 337