Service difficulty report · Sensor · Doug DC983

Difficulty date
February 19, 2007
Submitted
February 27, 2007
Operation
Air carrier
Aircraft
N861GA
Make and model
Doug DC983
Aircraft serial
49557
Part
Sensor
Part number
AYLF97321
Part serial
11835
Condition
Out Of Adjust
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 516 IDA/LAS - FLIGHT CREW REPORT "L ICE PROTECT TEMP HIGH" ANNUNCIATOR ILLUMINATED WITH AIRFOIL ANTI-ICE ON. QRH PROCEDURE APPLIED AND LIGHT EXTINGUISHED. LAS VEGAS MAINTENANCE TROUBLESHOT THE SYSTEM TO A FAULTY LT TEMPERATURE SENSOR. REMOVED AND REPLACED TEMP SENSOR PER AMM 30-10-06. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED PER 30-10-00. THE AIRPLANE HAS RETURNED TO SERVICE.