What was found
CRACK IN FLOORBEAM UNDER CLS ADAPTER AT FRAME 34 BETWEEN TRACK 3L AND 4L (SEEN FROM FWD PIT). REMOVED AND REINSTALLED FLOORPANEL FOR FOM IAW A310-200 AMM SUPP 53-10-25-4. REMOVED AND REINSTALLED CLS ADAPTER IAW A310-200 SRM 51-40-21. REMOVED CRACK IAW A310 SRM SUPP 53-10-15 FIG 201 SHT 2. FABRICATED, LOCATED, AND DRILLED REPAIR ANGLES IAW A310-SRM SUPP 53-10-15. INSTALLED REPAIR IAW A310 SRM 51-40-21. REPROTECTED AREA IAW A310 SRM 51-75-10.