What was found
AFT MAIN CABIN AFT RT OUTBD SEAT TRACK, EXISTING SPLICE REPAIR BETWEEN STA 1853 TO 1871 X= -100 APPROX PERFORMED GVI IAW EO 8-5100-7-5001 P2 CRITERIA, FOUND CORROSION WITH EXFOLIATION AROUND HEADS OF FASTENERS ON SPLICE SEAT TRACK. REMOVED FASTENERS IAW SRM 51-30-00 VOL 2. REMOVED CORROSION AND VERIFIED LIMITS IAW SRM 53-70-00 FIG 5 VOL 1. NOMINAL THK IS .132, RESIDUAL THK IS .122, MTRL REMOVED IS .010, MAT REMOVED IS 7.5 PERCENT. TREATED REWORKED AREA IAW SRM 51-21-01 VOL 2 AND REINSTALLED FASTENERS IAW SRM 53-70-00 FIG 6 VOL1 AND SRM 51-30-00 VOL 2, MAT REMOVED IS WITHIN LIMITS IAW SRM 53-70-00 FIG 5 VOL 1.