What was found
CTR CARGO COMPT SUMP AREA FOUND SEVERE CORROSION ON BEAM AT STA 1721 LONG NR 45 LT. REMOVED CORROSION IAW SRM 51-21-01 VOL 2 PAR 34. MAX REMOVED IS .056", REMAINING MAT IS .035", PERCENT REMOVED IS 61 PERCENT, ORIGINAL THK .091". OUT OF LIMITS IAW SRM 53-15-01 VOL 3 FIG 6 AND SRM 53-00-01 VOL 1 FIG 1B. VERIFIED BY NDT INSPECTION SEE JPF. FAB AND INSTALLED NEW PART IAW SRM 53-60-01 VOL 1 FIG 3. REPLACED FASTENERS IAW SRM 51-35-01 AND SRM 51-33-01 VOL 2. REPROTECTED AREA IAW SRM 51-21-01 VOL 2 PAR 31-24.