What was found
PREVIOUS REPAIR LOCATED ON MAIN CABIN FLOORBEAM FRAME 37 AND BETWEEN SEAT TRACKS 4 AND 5 LT HAS 2 REPAIR ANGLES MEASURING 16.8" BY 1.7" LONG LOCATED AT THE UPPER FLANGE AREA, FWD AND AFT SIDE OF FLOORBEAM. PREVIOUSLY INSTALLED REPAIR LOCATED ON MAIN CABIN FLOORBEAM FRAME 37 BETWEEN SEAT TRACKS 4 AND 5 LT UPPER FLANGE AREA WAS DETERMINED NOT TO BE IAW A310 SRM SUPPLEMENT 53-10-15 FIG 201 SHEET 2, DUE TO MISSING 2 EACH HILOCKS AT TOP FLANGE ON FWD AND AFT CENTER ANGLES AT THE CLS ADAPTER BETWEEN THE FASTENERS WITH A PITCH OF 2.800". DRILLED, COUNTERSUNK, AND INSTALLED 2 HILOCKS PER A310 SRM SUPPLEMENT 53-10-15 FIG 201 SHEET 2.