What was found
HYD 3 FAIL, QTY .1 LOWERED GEAR VIA ALTERNATE EXTENSION FOUND LEAK IN CENTER GEAR AT HYD LINE ADJACENT TO RMPS. REPAIRED CRACK AT FERREL WITH RYNGLOK PER MM 20-10-01-2. SERVICED NR 3 HYD RESERVOIR TO FULL AND LEAK CHKS OK PER SMP. NEED ALTERNATE RELEASE CONTROL LEVER NOSE/MAIN GEAR STOWED. RESET ALTERNATE GEAR EXTENSION LEVER PER REF TO MD-11 WORK CARD 32T3601 REVISION NR 0001, 11-FEB-2004. SYSTEM OKAY FOR SERVICE AT THIS TIME.