As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK CARGO FRAME FOUND DENT AT STA 1641. REPAIR CARRIED OUT AS PER SRM 53-30-00 FIG. 1 VOL.I. REPETITIVE INSPECTION REQUIRED, INITIAL INSPECTION AT 14,500 CYCLES TO BE CARRIED OUT AND THEREAFTER 9500 CYCLES AS PER SRM 53-30-00 FIG.1. VOL.I. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM CHAPTER 6-2-100. ITEM TRANSFERRED TO OPEN ITEMS LIST CONTROL NO. 309719.