What was found
FOUND UPPER CARGO COMPARTMENT, RT SIDEWALL FRAME AT STA 1701 INNER CHORD DENTED AT L-12R. UPPER CARGO COMPARTMENT, RT SIDEWALL FRAME AT STA 1701 AT L-12R REPAIR CARRIED OUT AS PER SRM 53-30-00 FIG.1 VOL.I. REPETITIVE INSPECTION REQUIRED. INITIAL INSPECTION AT 14500 CYCLES AND THEREAFTER 9500 CYCLES, INSPECTION TO BE CARRIED OUT AS PER SRM 53-30 -00 FIG. 1 VOL.I. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM 6-2-100. ITEM TRANSFERRED TO OPEN ITEMS LIST CONTROL NR 0311190.