What was found
FOUND UPPER CARGO COMPARTMENT, LT SIDEWALL FRAME AT STA 1701 INNER CHORD DENTED AT L- 12L. UPPER CARGO COMPARTMENT, LT SIDEWALL FRAME AT STA 1701 AT L-12L REPAIR CARRIED OUT AS PER SRM 53-30-00 FIG.1 VOL.I. REPETITIVE INSPECTION REQUIRED - INITIAL INSPECTION AT 14500 CYCLES AND THEREAFTER 9500 CYCLES, INSPECTION TO BE CARRIED OUT AS PER SRM 53-30-00 FIG. 1 VOL.I. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM 6-2-100. ITEM TRANSFERRED TO OPEN ITEMS LIST CONTROL NR 0311188.