What was found
LT SIDE INSIDE FUSE, FS 47, BETWEEN STR 12L AND 13L GOUGED FRAME. COMPLIED WITH FEDEX EA NR 6-5310-105186 TITLE FUSELAGE, MINOR NICKS IN FRAME 47 STRINGER 12L-13L AND 12R - 13R REPAIR, BLENDED 2 AREAS WITH A MAXIMUM DEPTH OF .077 ON THE INBD CORNER AS NOTED IN FIGURE 1 ARE STRUCTURALLY ACCEPTABLE PROVIDED A MIN 63 MICRO INCH FINISH IS MAINTAINED, TOUCH UP ALODINE AND FR PRIMER PER SRM CHAPTER 51.