As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK AT FS 480 FLOORBEAM CORRODED BETWEEN LBL 26 AND LBL 45. REMOVED CORROSION REF SRM 53-10-01. ORIGINAL MATERIAL MEASURED AT .125 BLEND OUT MATERIAL LOSS AT DEEPEST LOCATION MEASURES .016. REMAINING MATERIAL AFTER BLEND IS .109 AND IS STRUCTURALLY ACCEPTABLE PER EA 7-5310-106996. ACCOMPLISHED HFEC INSPECTION TO EFFECTED AREA REF EA AND SOPM 20-10-03 WAS USED TO ACCOMPLISH FLAP PEEN TO AREA.