What was found
LOWER AFT PIT FLOORBEAM, VERTICAL CHANNEL HAS CORROSION AT LWR END AROUND FASTENER HEAD AT STA 950E, LBL 8 FABRICATED NEW FLOORBEAM VERTICAL CHANNEL AT STA 950E, LBL 8. HEAT TREATED AND HARDNESS TESTED FOR 7075 T6 CONDITION REF BAC DWG 69-44559 AND BAC 5602 REV AF 28AUG01 AND BAC 5946 REV AA 9JUL06, ON SHOP WO NR 11841-1600-0003. REINSTALLED FLOOR SUPPORT REF BOEING DWG 69-44559 AND SRM 51-30-2.