What was found
LWR AFT PIT BILGE, STA 950A LBL 8" OB LWR FLANGE OF KEEL BEAM CHORD HAS APPROX 6 SQ INCHES OF CORROSION ON UPPER SURFACE. REMOVED CORROSION ON OUTBOARD FLANGE OF KEEL BEAM LWR AFT PIT BILGE STA 950A, 6" LBL 8" FOUND AREA OUT OF LIMITS. FABRICATED, TREATED AND PRIMED REPAIR, STRAP/FILLER AND INSTALLED REF EO NR 7-5310-7-2356C1 PART 3, NOTE 1 OF FIG 3, PG 2.