What was found
PREVIOUS REPAIR LOCATED ON MAIN CABIN FLOORBEAM FRAME 55/58 BETWEEN SEAT TRACK 4 AND 5 RT, AFT UPPER FLANGE HAS 1 REPAIR ANGLE MEASURING 12.6" BY 2.6", ALSO THERE IS A REPAIR FILLER ON THE TOP SURFACE OF FLOORBEAM UNDER THE CLS ADAPTER MEASURING 14.3" BY 1" PREVIOUSLY INSTALLED REPAIR FOUND NOT TO BE IAW SRM OR REPAIR DWG. REMOVED EXISTING REPAIR AND CLS ADAPTER, REPLACED THE CLS ADAPTER WITH A NEW PART AND REPAIRED THE FLOORBEAM PER FEDEX EA6-5310-110461 AND REPAIR DWG R53270150.