Service difficulty report · Floorbeam · Airbus A310203

Difficulty date
May 15, 2007
Submitted
May 15, 2007
Operation
Air carrier
Aircraft
N401FE
Make and model
Airbus A310203
Aircraft serial
191
Aircraft time
32,744 hours, 28,923 cycles
Part
Floorbeam
Condition
Misrepaired
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PREVIOUS REPAIR LOCATED ON MAIN CABIN FLOORBEAM FRAME 60 BETWEEN SEAT TRACK 3 AND 4 LT, FWD AND AFT SIDES HAVE 2 EACH REPAIR ANGLES AND 2 EACH REPAIR STRAPS. THE FLOORBEAM HAS A NEW SECTION REPLACED ON THE LEFT SIDE PREVIOUSLY INSTALLED REPAIR FOUND NOT TO BE IAW A310 SRM SUPPLEMENT 53-10-15 FIG 201 SHEET 10. REMOVED 16EA 3/16 LOCK FASTENERS REAMED HOLES TO .250 AND INSTALLED 16 EACH HL10VF8 LOCK FASTENERS REPAIR IS IAW A310 SRM SUPPLEMENT 53-10-15 FIG 201 SHEET 10.