What was found
VERTICAL STAB RT SIDE AT INTERSECTION OF ACCESS PANELS 323AL AND 323BR APPROX 2.5 INCHES FROM VERTICAL LOWER RIB EDGE 2 EACH WEAR MARKS APPROX .200 IN DIAMETER AND .050 DEEP BLENDED CHAF MARKS IAW A310 SRM 51-73-10 CHECKED LIMITS IAW A310 SRM 55-30-00 (OUT OF LIMITS). CUT OUT DAMAGE IAW A310 SRM 55-31-12 PB201 VERIFIED MATERIAL ID IAW A310 SRM 55-31-12. FABRICATED DOUBLER IAW A310 SRM 55-31-12. ALODINED DOUBLER IAW A310 SRM 55-31-*12 PRIMED DOUBLER IAW A310 SRM 55-31-12. INSTALLED DOUBLER IAW A310 SRM 55-31-12, HEAT TREATED RIVETS IAW A310 SRM 51-25-00 TOP COATED TO MATCH IAW A310 SRM 51-75-10.