What was found
PREVIOUS REPAIR LOCATED ON MAIN CABIN FLOORBEAM FRAME 36 BETWEEN SEAT TRACKS 2 AND 3 RT FWD SIDE UPPER FLANGE HAS 1 REPAIR ANGLE MEASURING 8.6" BY 2.4" AND TWO .250 STOP DRILLED HOLES, THE INBOARD STOP DRILL HOLE HAS A CRACK CONTINUING PAST THE DRILL STOP (0.5 INCH CRACK) PREVIOUSLY INSTALLED REPAIR FOUND NOT TO BE IAW FEDEX EA 6-5321-45448. REMOVED EXISTING PREVIOUS REPAIR AND REPAIRED PER FEDEX EA6-5310-110483. REMOVED AND REINSTALLED FLOOR PANEL 232XH IAW A310/200 AMM SUPPLEMENT 53-10-23.