What was found
AFT PIT, STA 1166, WL 200, RBL 48, AFT WALL SUPPORT ANGLE, IS CORRODED UPPER AFT CORNER. BLENDED CORROSION AND FOUND ANGLE TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW ANGLE, REF SRM 51-30-2 PG 1-4, AND BOEING DWG NR 65-67251.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, STA 1166, WL 200, RBL 48, AFT WALL SUPPORT ANGLE, IS CORRODED UPPER AFT CORNER. BLENDED CORROSION AND FOUND ANGLE TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW ANGLE, REF SRM 51-30-2 PG 1-4, AND BOEING DWG NR 65-67251.