As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT GEAR DOOR EXTERIOR SURFACE HAS AN AREA OF DELAMINATION APPROX 6" IN DIAMETER IN THE CENTER OF THE COMPOSITE FAIRING, AREA MARKED. REMOVED DAMAGE SKIN IAW SRM 51-77-10. CLEANED AND PREPPED DAMAGE AREA IAW SRM 51- 70-10 MIXED RESIN, FABBED REPAIR PLIES, MIXED BONDING RESIN AND BONDED PLIES IAW SRM 51-7710. APPLIED PRIMER IAW SRM 51-77-10 AND PAINTED REPAIR AREA IAW SRM 51-75-10.