What was found
ATB - AFTER T/O - ECAM AND OVH SYS 2 FLAP FAULT. UNABLE TO CLEAR FAULT. FOUND NR 2 SFCC FAULTING MAIN CONTROL VALVE UPON ARRIVAL. RESET SFCC AND RAN FLAPS, AGAIN FAULTED MAIN CONTROL VALVE. BOTH TIMES NR 2 FLAP SYS FAULT LIGHT ON OVERHEAD CAME ON AND WOULD NOT RESET. SWAPPED NR 2 AND NR 1 SFCC AND RAN FLAPS. FLAP SYS NR 1 BEGAN FAULTING. PUT BOXES BACK IN ORIGINAL POSITION. PLACING BOX ON ORDER. RAN NR 2 ENG AND TIMED FLAPS WITH NR 2 SFCC BREAKERS PULLED PER AMM 27-54-00-5. ALL TIMES WERE WITHIN LIMITS AND FLAPS MOVED SYMMETRICALLY ON SYSTEM NR 1. REPLACED NR 2 SFCC FLAP/SLAT SYSTEM TEST OK PER MM 27-51-18-4 27-51-00-5.