What was found
CTR LANDING GEAR, RT TRUNNION FITTING ALIGNMENT HOLE FOUND CORRODED. [07-10-07] REMOVED AND FOUND WITHIN LIMITS AS PER SRM 53-40-00 FIG. 16 VOL.I. ORIGINAL HOLE DIAMETER: 1.500"; REWORKED HOLE TO 1.6664". MAXIMUM HOLE DIAMETER: 1.680". BUSHING FABRICATED AND INSTALLED AS PER SRM 53-40-00 FIG.16 VOL.I. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM 6-2-100.