What was found
AFT PIT SHEAR TIE CORRODED STA 950F BETWEEN STR 27 R-28R RBL 17 - 22 REMOVED CORROSION AT STA 950F, STR 27-28R, RBL 17-22, IAW SRM 53-10-1 PG 2, NDT FOR MATERIAL LOSS, ORIGINAL THICKNESS .063". REMAINING THICKNESS IS .058" . WITHIN 10% LIMIT IAW SRM 53-10-1 PG 1. TREATED AND PRIMED AFFECTED AREA SRM 51-10-2.