What was found
ALC UNDER FLOOR CORROSION ON STR 49 L BETWEEN FR 64 AND 65 IN WORK. 09-04-07 REMOVED CORRODED STRINGER IAW A310 SRM 51-40-21 PG 23, LOCATED DRILLED AND INSTALLED STRINGER AND SPLICE IAW A310 SRM 53-10-14 PG 201, 51-40-40.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ALC UNDER FLOOR CORROSION ON STR 49 L BETWEEN FR 64 AND 65 IN WORK. 09-04-07 REMOVED CORRODED STRINGER IAW A310 SRM 51-40-21 PG 23, LOCATED DRILLED AND INSTALLED STRINGER AND SPLICE IAW A310 SRM 53-10-14 PG 201, 51-40-40.