What was found
FUSELAGE MAIN DECK SEAT TRACK 2L GOUGED ON I/B FLANGE, AROUND 6 FASTENER HOLES BETWEEN FRAMES 47-51 (ZONE 240) REF A300-600 SRM 51-10-00 TOTAL AREA GOUGED 6 INCHES APPROX. BY .010 DEEP. BLENDED DAMAGE PER A300-600 SRM 51-73-10 AND FOUND TO BE OUT OF LIMITS PER A300-600 SRM 53-10-16 PB 101. REMOVED DAMAGED SEAT TRACK SECTION PER A300-600 SRM 51-72-10. FABRICATED NEW SEAT TRACK SECTION PER A300-600 SRM 53-15-16 AND DRAWING A53812915. ALODINED, PRIMED AND TOP COATED SEAT TRACK SECTION PER A300-600 SRM 51-21-10 AND 51-75-10. INSTALLED SEAT TRACK SECTION ASSY PER A300-600 SRM 51-72-10.