What was found
FRAME FITTING C33 IS CRACKED AT RBL 60 FWD PIT FLOOR LEVEL. 08-30-07 REMOVED SLANTE PANEL 132JW, XY GUIDE, RAILS, TRANSITION PANEL TO FOM. REMOVED FITTING, RECEIVED NEW FITTING A5377364420100 PO 582198.2. LOCATED AND DRILLED FITTING IAW A310 SRM 51-40-40, INSTALLED FITTING IAW A310 SRM 51-40-21 PARA 7, INSTALLED TRANSITION PANEL IAW A310 SRM 51-40-21 PARA 7. INSTALLED LATCH XY GUIDE AND RAILS IAW A310 AMM 25-52-44-4 AND 25-52-48-4. INSTALLED SLANTE PANEL 132JW IAW FEDEX A310 AMM 52-54-10-2 PART 2 B1.