What was found
MDCC AT FR 24 BETWEEN STG 11R AND 15R HAS 4 EA GOUGES APPROX 4 " ZONE 230 REF A300- 600 SRM 51-10-00. BLENDED GOUGES (4EA) FR 24 BETWEEN STR 11R AND 15R IAW A300 SRM 51-73-10 1 EA AREA OUT OF LIMITS IAW A300 SRM 53-10-00 PG 101 B=.63 A=0.50 L= .013. FABRICATED REPAIR ANGLE IAW A300-600 FREIGHTER SRM 53-10-13 FIG 202. ALODINED REPAIR IAW A300 SRM 51-21-10. PRIMED REPAIR IAW A300 SRM 51-75-10. INSTALLED REPAIR IAW A300-600 FREIGHTER SRM 53-10-13 FIG 202.