What was found
AFT PIT FRAME 67 BETWEEN STRINGER 49R AND 50R DENTED FORMED FRAME TO ORIGINAL CONTOUR REF: A310-200 SRM 51-73-10. PERFORMED HFEC, INSPECTION OF AREA IAW A310-200 NTM 51-10-08, NO CRACKS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FRAME 67 BETWEEN STRINGER 49R AND 50R DENTED FORMED FRAME TO ORIGINAL CONTOUR REF: A310-200 SRM 51-73-10. PERFORMED HFEC, INSPECTION OF AREA IAW A310-200 NTM 51-10-08, NO CRACKS NOTED.