What was found
FWD PIT, FRAME FITTING CRACKED, FR38 (X2082), BL 60L (Y1520), AT PIT FLOOR LEVEL.. REMOVED CRACKED FITTING IAW FEDEX A31 SRM 51-40-21 LOCATED DRILLED NEW FITTING PO 583026.6 IAW FEDEX SRM 51-40-44 PARA2. INSTALLED NEW FRAME FITTING IAW FEDEX SRM 51- 40-27 PARA 7.