As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER HFEC INSPECTION FOUND 18MM LONG CRACKS IN GANTRY BEAM 3 LT AND RT AT FRAME 49 LOWER INBOARD FLANGE. CRACK REPAIR PERFORMED ON FRAME 49 GANTRY 3 LT AND 3 RT PER DRW R538-10426 WITH ENLARGED DIAPHRAGM WORK AREA WHILE MAINTAINING AN EDGE DISTANCE OF 1.5 RIVET DIAMETER IAW EA 6-5315-99180 AND RAS 044008/013/2006 ISSUE A.