What was found
FWD PIT LT SIDE PANEL SUPPORT HAS CORROSION ON LOWER SURFACE AT FR 36 LBL 50 REMOVED NUTPLATES AND CORROSION IAW FEDEX A310 SRM 51-40-21 AND 51-74-10. FOUND TO BE OUT OF LIMITS IAW FEDEX A310 SRM 53-10-00. REMOVED AND REINSTALLED LT SLANT PANELS CARGO GUIDE RAILS, TRANSITION PANELS, MOUNTS AND ROLLER TRAYS FROM FR 23-38.2 IAW FEDEX A310 AMM 25-54-10-2. FABRICATED T-CAP AND SPLICE ANGLE IAW FEDEX A310 SRM 53-10-15 ALODINED IAW FEDEX A310 SRM 51-21-10. PRIMED AND PAINTED IAW A310 SRM 51-23-10. INSTALLED T-CAP AND SPLICE ANGLE IAW FEDEX A310 SRM 53-10-15 AND 51-40-21. PDU OPS GOOD IAW FEDEX A310 AMM 25-52-26-4, MINOR REPAIR.