What was found
MAIN DECK - STA 1601, LONGERON 10R-11R FRAME FOUND DENTED. 09-26-07 REPAIR CARRIED OUT AS PER SRM 53-30- 00 FIG. 1 VOL.I. DAMAGE TOLERANCE INSPECTION REQUIREMENT REQUIRES INITIAL INSPECTION AT 14500 CYCLES FROM THE CURRENT 9821 CYCLES AND REPETITIVE INSPECTION AT 9500 CYCLES THEREAFTER. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM 6-2-100.