What was found
FOUND FRAME-STRINGER-CONNECTING ANGLES WITH LESS EDGE MARGIN AT STRINGER 26 RT BETWEEN FRAME 67-68, 69-70 AND 71-72 AND ON STRG 26 LT BETWEEN FRAME 70-71 AND 71-72. REPLACEMENT WITH FABRICATED ENLARGED REPAIR ANGLES IAW SRM 51-72-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FRAME-STRINGER-CONNECTING ANGLES WITH LESS EDGE MARGIN AT STRINGER 26 RT BETWEEN FRAME 67-68, 69-70 AND 71-72 AND ON STRG 26 LT BETWEEN FRAME 70-71 AND 71-72. REPLACEMENT WITH FABRICATED ENLARGED REPAIR ANGLES IAW SRM 51-72-10.