What was found
CRACKED FITTING BETWEEN STRG 45-47 RT AT FRAME 67, CARGO COMP FLOOR STRUCTURE. REPLACEMENT OF FITTING IAW SRM 51-72-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FITTING BETWEEN STRG 45-47 RT AT FRAME 67, CARGO COMP FLOOR STRUCTURE. REPLACEMENT OF FITTING IAW SRM 51-72-10.