As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PREVIOUS DAMAGE: LT FUSE (SAT 680) STR 14L, FRAME ABOVE 14L HAS DEEP GOUGES BLENDED DAMAGED AREA ORIGINAL MATERIAL .045" MATERIAL LOSS .015" MATERIAL REMAINING .030" AND IS OUT OF LIMITS REF SRM 53-10-1. REMOVED DAMAGED SECTION, FABRICATED REPAIR SPLICE. INSTALLED NEW FRAME SECTION AND FRAME REPAIR SPLICE REF EA NR 7-5310-113101-FUSELAGE-MAIN FRAME.