What was found
MAIN DECK COMPARTMENT AT STA 1701 STRINGER 12R AREA FRAME EDGE FOUND CHAFED. 10-9-07 CARRIED OUT REPAIR AS PER SRM 53-30-00 FIGURE 1 VOLUME I. DUE TO CAT B REPAIR, INITIAL INSPECTION IS REQUIRED AT 14,500 CYCLES AND REPETITIVE INSPECTIONS REQUIRED AT EVERY 9,500 CYCLES. THIS REPAIR IS CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.