As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND BETWEEN FRAME 67 AND FRAME 64 RBL44 FLOOR SUPPORT STRUCTURE IS CORRODED. 10-22-07 REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW A310 SRM 53-10-00; REMOVED AND REPLACED SUPPORT STRAP IAW A310 SRM 53-17-14 ITEM 1 FIG 9, AND 51-40-44 AND 51-40-21.