What was found
CABIN FRAME 44 TIE CLIP TO LT EMERGENCY DOOR CUT OUT FRAME AT FLOOR LEVEL IS CORRODED. REMOVED CORRODED TIE CLIP IAW FEDEX A310-200 SRM 51-40-21 PARA 7, RECEIVED, LOCATED, AND DRILLED NEW FITTING PO NR 589661.1 IAW FEDEX A31-200 SRM 51-40-30. INSTALLED NEW FITTING IAW FEDEX A310-200 SRM 51-40-21 PARA 7.