What was found
AFT PIT STRINGER SPLICE REPAIR AT STRINGER 52L FRAME 60/61 REQUIRES EVALUATION FOR MAJOR/MINOR DETERMINATION AND IF REPAIR WAS ACCOMPLISHED USING FAA APPROVED DATA. FOUND THAT STGR COUPLING MATERIAL TYPE AND MATERIAL TEMPER DID NOT CONFORM TO A310 SRM REQUIREMENTS, REMOVED AND REPLACED STRINGER COUPLING REPAIR IAW A310 SRM 53- 10-14 FIG 201