What was found
13TH LT WINDOW PLUG AFT OF AFT OVERWING EXIT HAS CORROSION ON EXT SURFACE INSTALLED NEW WINDOW PLUG REF MM 56-20-000-4 APPLIED CIC TO INTERIOR REF SRM 51-10-2, PAINTED TO MATCH SRM 51-10-2. THIS IS CLASSIFIED AS A MINOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
13TH LT WINDOW PLUG AFT OF AFT OVERWING EXIT HAS CORROSION ON EXT SURFACE INSTALLED NEW WINDOW PLUG REF MM 56-20-000-4 APPLIED CIC TO INTERIOR REF SRM 51-10-2, PAINTED TO MATCH SRM 51-10-2. THIS IS CLASSIFIED AS A MINOR REPAIR.