What was found
MAIN DECK CARGO COMPARTMENT, RIGHT STA 1701 FRAME AT ABOUT STRINGER 12R AREA FOUND DENT. 11-05-07 CARRIED OUT REPAIR AS PER SRM 53-30-00 FIGURE 1 VOLUME I. DUE TO CATEGORY B REPAIR, INITIAL INSPECTION IS REQUIRED AT 14,500 CYCLES WITH REPETITIVE INSPECTIONS AT EVERY 9,500 CYCLES. REPAIR CLASSIFIED AS MAJOR PER FEDEX GMM 6-2-100.