What was found
MAIN DECK FLOOR SUPPORT IS CORRODED, BS 328-344, LBL 29, WL 208. REMOVED CORROSION IAW SRM 51-10-6, FOUND TO BE OUT OF LIMITS ORIGINAL .080'. REMOVED .025" (DEEPEST POINT ) REMAINING .055', IAW SRM 53-10-01, TOOL AAR IND -0213, CAL DUE 10-15-08. REMOVED FLOOR SUPPORT, FABRICATED, TREATED AND PRIMED, AND INSTALLED FLOOR SUPPORT, AND FILLER IAW SRM 51-30-2, 51-10-2, 51-20-1, AND BOEING DWG, 65-17593. THIS IS CLASSIFIED AS A MINOR REPAIR.