What was found
LOWER FUSELAGE STATION 742, RBL 1 TO RBL 4, KEEL BEAM LOWER WEB CORRODED, REMOVED CORROSION IN REF TO SRM 51-10-1 PG 1, ORIG MAT'L .080, MAT'L REMAINING .045', OUT OF LIMITS. REMOVED DAMAGE AREA OF KEEL BEAM WEB 51-10-2 PG 10. FABRICATED DOUBLER AND FILLER IN REF TO SRM 51-40-2 FIG 1. TREAT AND PRIMED DOUBLER AND FILLER AND INSTALLED REF MM 51-20-021-07, MM 51-20-031-07.