What was found
BODY FAIRING FRAME HAS CORROSION LOCATED FORWARD END OF PANEL 3455R. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS, ORIGINAL .050'. REMOVED .025", REMAINING .025", IAW SRM 53-10-1. TOOL AAR23841 CAL DATE .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BODY FAIRING FRAME HAS CORROSION LOCATED FORWARD END OF PANEL 3455R. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS, ORIGINAL .050'. REMOVED .025", REMAINING .025", IAW SRM 53-10-1. TOOL AAR23841 CAL DATE .