As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT FLOOR SUPPORT PNL IS CORRODED BS 480-720D, LBL 20-26, WL 157. BLENDED CORROSION AT BS 480 TO 720C +10. MAX MATERIAL LOSS OF 16 PERCENT OF .050 ORIG "T". WITHIN LIMITS REF SRM 53-10-1 PG 31. BLENDED CORROSION AT BS 720C+10 TO BS 720D. MATERIAL LOSS OF 30 PERCENT OF .050" ORIG "T" FOUND TO BE OUT OF LIMITS REF SRM 53-10-1. FABRICATED AND REPLACED Z- ANGLE PANEL AT BS 720C+10 TO 720D, REF 51-30-2, 51-10-2 AND BOEING DWG 69-46373 THIS IS CLASSIFIED AS A MINOR REPAIR.