What was found
FOUND AFT PIT STR 47R AT FRAME 59 IS GOUGED ON UPPER SURFACE. REMOVED GOUGE ON STRINGER 47R IAW FEDEX A310 SRM 51-73-10, STRINGER 47R OUT OF LIMITS IAW A310 SRM 53-10-00. REMOVED IEA SHEAR TIE AT FRAME 59 BETWEEN STRINGER 47R AND 48R IAW A310 SRM 51-40-21 PG 23-27. REMOVED DAMAGE STRINGER SECTION IAW A310 SRM 52-10-14 203/204 FIG201. LOCATED AND DRILLED NEW STRINGER SECTION IAW A310 FABBED REPAIR COUPLING IAW A310 53-10-14PG 203/204 FIG 201 ALODINED REPAIR PARTS IAW A310 SRM 51-21-10 PRIMED AND TOP COATED REPAIR PARTS IAW A310 SRM 51-23- 10 INSTALLED NEW STRINGER SECTION AND COUPLING IAW A310 53-10-14 PG203/204 FIG201. INSTALLED SHEAR TIE IAW A310 SRM 51-40-21 PG 23-27.