What was found
PREVIOUS REPAIR LOCATED IN BULK CARGO ON FRAME 64 UNDER FLOOR BETWEEN STRINGER 46 AND 48 RT HAS 2 EACH REPAIR ANGLES ON THE AFT SIDE MEASURING 14.4" BY 2.9" AND 13.6" BY 2.2" PREVIOUS INSTALLED REPAIR WAS DETERMINED NOT TO BE IAW FEDEX EA6-5310-68347, DUE TO 15 EACH INCORRECT FASTENERS INSTALLED, BASED ON A VISUAL EVALUATION. REMOVED 15 EACH MS20470DD6 RIVETS, REAMED HOLES TO 1ST OVERSIZE AND INSTALLED 15 EACH LOCK FASTENER IAW A300-600 SRM 51-40-21 AND REF FEDEX EA6-5310-68347. REPAIR IS CLASSIFIED AS A MAJOR PER FED EX GMM 6-2-100.