What was found
MAIN DECK CARGO, LEFT SIDEWALL STRUCTURE FRAME AT STA 1741 LONGERON 12L FOUND CRACKED. REPAIRED AS PER SRM 53-30-00 FIGURE 1 VOLUME I. DUE TO CATEGORY B REPAIR, INITIAL INSPECTION REQUIRED AT 14,500 CYCLES AND REPETITIVE INSPECTIONS EVERY 9,500 CYCLES. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.