What was found
LWR FWD CARGO PIT, INNER SKIN IN BILGE HAS PITTING CORROSION UNDER LEVELING COMPOUND, STA 680 PLUS 5, LBL 8". CUT OUT DAMAGE, FABRICATED DOUBLER AND INSTALLED DOUBLER, REF SRM 53-30-3 FIG 1. REPAIR IS CLASSIFIED AS A MINOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.