What was found
FWD LAV, I/B WALL, ATTACH ANGLE FROM WALL TO FLOOR STRUCTURE IS CRACKED, BS 315, RBL 15. REMOVED CRACKED ANGLE AND FABRICATED NEW SUPPORT ANGLE REF DWG 65-26173 AND SRM 51-30-2 PG 3. TREATED AND PRIMED AND APPLIED TOP COAT TO NEW ANGLE REF SRM 51-10-2 PG 1. INSTALLED SUPPORT ANGLE AT BS 315M RBL 15, REF SRM30-2 PG , THIS IS CLASSIFIED AS A MINOR REPAIR.